Device
D
Manufacturer
Merit Medical Systems, Inc.
Model: D Catalog: SC14150 DI: 00884450425275 Status: New MRI: Labeling does not contain MRI Safety Information Single-use: Yes Rx: Yes OTC: No
First Published: 2026-04-24 Current Version: 2026-05-04
Sterilization
Device Sterile: Yes
Sterilization Prior To Use: No
Regulatory & Distribution
Record Status: Published
Version Number: 1
Record Key: 701bce62-9d5d-4c29-8d69-a1c4b1431c7a
Distribution Status: In Commercial Distribution
DUNS Number: 184763290
Device Count: 1
DM Exempt: No
Premarket Exempt: No
HCT/P: No
Kit: No
Combination Product: No
Lot/Batch Tracked: Yes
Serial Number Tracked: No
Manufacturing Date Tracked: No
Expiration Date Tracked: Yes
Donation ID Number Tracked: No
Labeled Contains NRL: No
Labeled No NRL: No
Identifiers
Item #1 - Device ID: 10884450425272
Item #1 - Pkg Status: In Commercial Distribution
Item #1 - Pkg Quantity: 5
Item #1 - Device ID Type: Package
Item #1 - Contains DINumber: 00884450425275
Item #1 - Device ID Issuing Agency: GS1
Item #2 - Device ID: 00884450425275
Item #2 - Device ID Type: Primary
Item #2 - Device ID Issuing Agency: GS1
Item #3 - Device ID: 20884450425279
Item #3 - Pkg Status: In Commercial Distribution
Item #3 - Pkg Quantity: 5
Item #3 - Device ID Type: Package
Item #3 - Contains DINumber: 10884450425272
Item #3 - Device ID Issuing Agency: GS1
GMDN
Code: 10688
Name: Angiographic catheter, single-use
Definition:
A thin, flexible tube designed to inject a contrast medium into select blood vessels of the cerebral, visceral, or peripheral vasculature during an angiographic procedure in order to facilitate the clear visualization of the vascular system of a targeted organ or area of the body. It is introduced percutaneously, has a radiopaque marker(s) for positioning, and may include disposable devices dedicated to catheter introduction/function [e.g., sheath(s)]. It may also be used for simultaneous pressure measurements to determine the transvalvular, intravascular, and intraventricular pressure gradients. This is a single-use device.
FDA Product Codes
DQY
Catheter, percutaneous
Device Sizes
Item #1 - Size Text: Max. Guide Wire Diameter-0.014"
Item #1 - Size Type: Device Size Text, specify
Item #2 - Size Text: Min. Introducer Sheath-4F
Item #2 - Size Type: Device Size Text, specify
Item #3 - Size Text: Effective Length-150 cm
Item #3 - Size Type: Device Size Text, specify
Item #4 - Size Text: Hydrophilic Coating Length-40 cm
Item #4 - Size Type: Device Size Text, specify